E-mail: ersanteknoloji@gmail.com

Keywords: Variable Frequency Drive, Soft Starter, VFD

V70 series

Home > Products > V70 series

  • V70 series

  • V70 series

  • V70 series

  • V70 series

  • V70 series

  • V70 series

  • V70 series

  • V70 series

  • V70 series

V70 series

V70 Series Solar frequency inverter ERSAN V70 Series […]

V70 Series Solar frequency inverter

ERSAN V70 Series Solar VFD, the excellent MPPT function enables the efficiency to reach 99.9%. It can track the light automatically throughout the day and can drive a variety of different types of pumps (for example: permanent magnet synchronous, asynchronous motors, etc.), And it contains water level control parameter group especially.

 

Product Description

ERSAN V70 Series Solar VFD, the excellent MPPT function enables the efficiency to reach 99.9%. It can track the light automatically throughout the day and can drive a variety of different types of pumps (for example: permanent magnet synchronous, asynchronous motors, etc.), And it contains water level control parameter group especially. High performance with multiple protection functions. Direct air ducts up and down, DC fans dissipate heat. Standard 485 communication design, that is convenient for networking to monitor the inverter. It support PID control and AC & DC dual power supply. Our solar frequency drives are suitable for farmland irrigation, residential water, landscape fountains, swimming pool water supply, desert management.

 

 

 

 

Technical Specification

 

ITEM SPECIFICATIONS
Main

Input

Recommended MPPT voltage range 80 ~350V DC input for 110V/160V/220V pumps, 0.75kw

150~400VDC for 220VAC/240V pumps with 0.75Kw to 4kw

250~800VDC, for 380VAC pumps with1.5kw to 160kw

Recommended input voltage 170Vmp DC for 110V AC pumps. 260Vmp DC for 160V AC pumps

350Vmp DC for 220V AC pumps, 620Vmp DC for 380V AC pumps

Maximum DC power input 1. 450VDC for 220AC output

2. 800VDC for 380V/480AC output

Motor type Control for permanent magnet synchronous motor and asynchronous motor pumps
Main output Output voltage 1 phase, 110V/160V/220V.

3 phase, 220V/380V/480V

Output frequency 0.5 Hz — 650 Hz
Control performance Control mode V/f control
Setting method of run command Outer terminal,

Keyboard panel

serial communication

Setting method of speed command Analog setting,

Keyboard,

Serial communication,

UP/DOWN speed setting from external terminal

Acceleration and Deceleration

Time

0-6000.0s
switching frequency 1.0 kHz ~ 10 kHz, according to junction temperature automatically reduce the switching frequency
Analog input Number 2 ways: AI1、AI2
Type DC voltage or DC current
Maximum input range AI1: 0 to 10VDC receivable

AI2: 0 to 10VDC or 0/4 to 20mA DC receivable

Analog output Number 2 way: AO1,AO2
Type DC voltage or DC current
Maximum input range AO1: 0 — 10V,

AO2: Maximum output high frequency is 50KHz,

output voltage 0~10V, current 0~20mA

 

logic input Number XI,X2,X3,X4,X5,X6(can used for high speed pulse input terminals)
logic output Number relay output 1、2(TA-TB-TC1、TA-TB-TC2)
pulse signal output Run state, Fault output, Frequency arrival
relay output TA-TB-TC, including a NO contact (TC) and a NC contact (TB)

Maximum switch capacity:

TA1-TC1/TA2-TC2: 3A @ 250VAC, or 1A@ 30VDC

TA1-TB1/TA2-TB2: 3A @ 250VAC or 1A @ 30VDC

Programmable transistorOutput Y Fault output, Frequency arrival, Over-torque warning
Serial communication interface RS485 interface supports Modbus protocol.
Motorprotection Grounding protection, over current protection,

output phase short circuit protection, over torque protection, motor overload protection, motor overheating protection (motor with PTC device)

Display 4-digit LED digital display For display of frequency setting, output frequency, fault code and parameter setting etc.
Environment Standard Development of V6 series frequency inverter follows strict international standards and relevant recommended IEC and EN standards for control devices, especially IEC/EN61800-5-1 and IEC/EN61800-3.
Altitude Dreading unnecessary when altitude is 1000m or below (Dreading necessary at altitude higher than 1000m)
Ambient environment Reliable operation at -10 ~ 50°C without debating. When top protective cover is taken off, the environment temperature can be as high as +50 °C. Above +50 °C, the current drops by 2.2% for each rise of 1 °C in temperature.

Storage: -25 ~ 70°C


Environment
Humidity No condensed water or drip at 5 ~ 95%, In accordance with IEC60068-2-3
Impact strength 15gn for continuous 11ms, In accordance with IEC/EN60068-2-27
Maximum antipollution capacity Class 2, in accordance with IEC/EN61800-5-1
Structure Protection level IP20
Cooling Method Forced Air cooling
Installation method Wall mounted

 

Packaging Details

Carton packing or wooden case packing, the size is variable according to different types and specifications of the frequency inverter.

 

 

 

FAQ

1. Are you trading company or manufacturer?

We are manufacturer.

 

2. What’s the production ability?

10000 pieces monthly and rush order for any quantity.

 

3. What kind of certificate you have?

We have CE and IS09001. etc.

 

4. Do you accept OEM business?

We accept OEM with your authorization

 

5. How is the after-sale service?

We offer spare parts accordingly and English-speaking  engineers offer online service.